Abstract
Introduction :
Ocular ultrasound can be used to supplement optical methods of exploring the eyeball when these are inaccessible. The aim of this study was to investigate the value of ultrasound in the management of ocular pathologies in the Ophthalmology Department of the Amirou Boubacar Diallo National Hospital in Niamey, Niger.
Materials and methods :
this was a cross-sectional study with prospective data collection over a six-month period a. All patients who underwent A-mode and/or B-mode ocular ultrasound during the study period were included.
Results :
In all, we collected 112 eyes from 102 patients, including 58 men and 44 women, giving a sex ratio of 1.31. The age group over 60 years was the most represented 59.00%. B mode ultrasonography was performed in 30% of patients (n=18), A+B-mode in 70.00% (n=71). Cataract was the main indication for B-mode ultrasound, with 68.62% (n=70), followed by trauma in 15.30% (n=16). B-mode ultrasound was normal in the majority of patients (71.84%, n=74). Among the abnormalities found, retinal detachment was the most frequent, accounting for 13.51%. For A-mode ultrasound, dioptric powers of 20-22 were the most common (mean = 20.27 D, extremes: 6.5 to 30.5 D).
Conclusion :
Ocular ultrasonography is a key examination in cases of disturbance of the transparent medium. cataract remains the main indication. of ocular ultrasonography and retinal detachment was the pathology most frequently found. The biometric value is standard in the majority of cases.
References
1. Poujol J. Toufic N. Indications et possibilités de 2456B l’échographie en ophtalmologie. Conférences lyonnaises d’ophtalmologie, 1980,144-145
2. Mundt GH, Hugues WE. Ultrasonics in ocular 2457B diagnosis. Am J Ophthalmol 1956; 41:488-98.
3. Oksala A, Lehtinen A. Diagnostic value of 2458B ultrasonics in ophthalmology. Ophthalmologica 1957 ;134 :387-95.
4. Bronson NR. Development of a Simple B-scan 2459B Ultrasonoscope. Trans Amer Ophthal Soc 1972 ;70:365-408.
5. Bergès, O, Koskas, P, Lafitte, F and Piekarski, J. 2460B Échographie de l’œil et de l’orbite avec un échographe polyvalent. Journal de Radiologie, 2006 ; 87(4) :345-353.
6. Silverman RH. High- resolution ultrasound 2461B imaging of the eye—a review. Clin Experiment Ophthalmol. 2009 Jan;37(1):54– 67.
7. Ousmane T, Bagayoko OL, Sanogo S, Dembélé M, 2462B Diallo OW, Diallo M et al. Mode B Ultrasound in the Study of the Posterior Segment in the Medical Clinic “Marie Curie” in Bamako Open Journal of Medical Imaging.2022, 12(3):138-146.
8. Francky KB, Timothée T, Heritier SB, Euloge BT. 2463B Pathologies du Segment Posterieur de L’Œil Observées à L’echographie au CHU Maman Elisabeth Domitien (Centrafrique). European Scientific Journal July 2019. 15 (21) :423-436.
9. Boniface IE, Augustine CO, Augustine OI, 2464B Samuel OM. Journal of Health Care for the Poor and Underserved 2013; 24(4):1440-1447
10. Bravo-Tsri Ake, Kouadio Af, Yao Bl, Kouassi 2465B Kpb , Kouakou Kv, Issa K. Échographie mode B des traumatismes oculaires à Bouaké (Côte d’Ivoire) : à propos de 56 cas. RISM 2023;25,2:122-
11. Balde Al, Camara F, Sow AS, Ba E. Apport de 2466B l’échographie B dans le diagnostic des affections oculaires au service d’ophtalmologie de l’hôpital Aristide Le Dantec de Dakar. Jaccr Africa 2020; 4(4): 46-50
12. Yaya, G, Bobossi Serengbe, G. and Gaudeuille, G. 2467B Les traumatismes oculaires chez les enfants de 0-15 ans. Aspects épidémiologiques et cliniques au CNHU de Bangui. Journal Français d’Imagerie Médicale, 2005; 28(7) :708-712.
13. Konan AN, Maiga MS, Sidibe M, Batcham A, 2468B Kouame N, Domoua AM. Contribution of mode B ultrasound in the diagnostic and therapeutic management of ocular pathologies in Abidjan. Le Mali Medical. 2021; 36(3):45-8.
14. Kofi-Mensa ST, Abel RA, Patricia Y, Zakari N, 2469B Olivier B, Vicentia B. Apport de l’échographie dans les traumatismes oculaires à Parakou (Bénin). Pan African Medical Journal. 2013; 15:114
15. Shinar Z, Chan L, Orlinsky M. Use of ocular 2470B ultrasound for the evaluation of retinal detachment. The Journal of emergency medicine. 2011 Jan;40(1):53–7.
16. Jean W D et all. Résultats fonctionnels de la 2471B chirurgie de la cataracte parphacoalternative avec implantation en chambre postérieure: à propos de 300 casà Bobo Dioulasso (Burkina Faso). Pan African Medical Journal. 2015; 20:230.
Metrics
Downloads

This work is licensed under a Creative Commons Attribution 4.0 International License.
Copyright (c) 2026 A Nouhou Diori, H Abdou Moussa, H Mahamat Tidjani, B Inoussa, L Laouali, H Abba Kaka, A Amza
